Aluminum Circuit Wiring

 HouseMaster Common Defects

Solutions Aluminum wiring was used in the 1970's for the wiring of receptacles and switches. Single stranded branch aluminum wiring, has been implicated with fires in houses. Aluminum does not conduct electricity as efficiently as copper and creates more resistance and heat.
The wire expands and contracts more than copper. The problem was compounded by screw heads which were too small at the devices. This expanding and contracting are susceptible to working the connections loose at the receptacles and switches. This is where a short can occur as oxidation builds up between the aluminum wires, and pose a potential fire hazard. Updated devices with larger screws were created however, these are not considered the best or only solution.

Some people feel the aluminum should be removed and copper replaced. There are some approved and accepted methods. Standard wire nuts are not approved for pig tailing and according to the Consumer Product Safety Commission may be a greater fire hazard and should be repaired.  

Approved Methods According to the Consumer Product Safety Commission Include:  

Copper pig-tails crimped onto the aluminum at all receptacles and switches. A special tool is used for this application.

UL approved wire nut connectors, filled with anti-oxidant cream, designed specifically for aluminum to copper connections. Secure connections as is on approved Al/Cu devices.  

Use antioxidant on all aluminum wiring connections.  

Approved receptacles and light fixtures with an aluminum rating.  

Monitor conditions such as flickering lights, voltage drop, or warm receptacles.

In any case, an electrician familiar with aluminum wiring should be consulted to verify proper connections. Multi stranded aluminum wiring is not part of this problem and of no concern. The majority of modern 220 amp rated houses are utilizing multi stranded aluminum wiring.  

Copper Clad Aluminum

Copper Clad Aluminum is easily mistaken for copper. It does not have the same problem with oxidation build up as does aluminum. It is typically a #12 wire and still needs proper devices with the larger screw heads or approved pig tailing methods. To identify Copper Clad Aluminum look for a silver color at the ends of the wires where they are connected to the grounding bar. Another location to identify Copper Clad Aluminum is in the attic or crawlspace. In these areas look for the identification on the wire sheathing. Such as CU Clad AL.

Homespecs Articles

Aluminum Circuit Wiring
Decks  
Hot Water Warning
Pre-listing Inspections  
Preparing your Home for an Inspection  
Polybutylene

Links

If you would like to arrange for any of our services call us at
(516) 942-0009 or (631)-243-6642
or
   Toll free at 1-877 814-4775
Please call 7 days a week from 9am to 9pm
Order "on-line" Inspection 
or
E-mail us at Homespecny@aol.com 

Back to Main Page